The glass reactor is stirred to form a circular reaction
Working principle of glass reactor
The glass reactor mainly makes use of its double-layer glass characteristic, we can place the reaction material (a kind of reaction solvent) in the intermediate interlayer, and conduct the stirring reaction under the atmospheric pressure or negative pressure. In this way, the medium inside the sandwich of the glass reactor (such as frozen liquid, heated water, or heated oil, etc.) is heated or cooled by stirring for a circular reaction. It is widely used as an ideal equipment in modern biochemical new material synthesis experiments.
When we use the glass reactor, we must operate in the correct way. Only in this way can we guarantee that the equipment can work normally. So what do we need to be aware of when using glass reactors? Let's take a look.
1. When operating the glass reactor, it shall be noted that the electrical part of the equipment shall not be flooded, and shall not be subject to moisture.
2. Secondly, read the instructions carefully before using the glass reaction kettle, and check the instruments: check whether the glass kettle body has any signs of damage, and whether the interfaces are consistent.
3. The PTFE switch everywhere shall not be tightened over-force to avoid damage to the glass. After stopping the machine, unscrew the PTFE switch, which will deform the PTFE piston in the working state for a long time.
4. During any repair or inspection, the glass reactor must first cut off the power supply and water supply.
5. Wipe each interface of the glass reactor with a clean soft cloth and smear a few rotary joints on the joint to make the vacuum grease on the joint even.
6. Turn on the power switch to make the machine run from slow to fast. When the machine is stopped, turn off the switch.
7. Do not wring the joint of the glass reactor too tightly, and check it regularly for loose and loose, so as not to cause the connector to bite dead.
8. Remove the sealing ring of the glass reactor under glass, check whether there is dirt on the shaft, wipe it with a soft cloth and then apply a little vacuum grease, and then re-install it to keep the shaft and sealing ring smooth.Clean the sealing ring regularly.
9. After the use of the glass reactor, the oil stains, stains and solvents remaining on the surface of the machine must be cleaned with a soft cloth.
10. When replacing the parts, the glass reactor must use the original parts produced by the original factory, and any other parts can cause fatal damage to the machine.
Copyright © Zhengzhou Well-known Instrument & Equipment Co.,Ltd. All Rights Reserved Sitemap